JISB7997-3 : 2020 排ガス中のダスト濃度自動計測器-第3部:摩擦静電気検出方式

JIS B 7997-3:2020の規格概要

この規格 B7997-3は、排ガス中にプローブ状の電極を挿入したとき,ダストが電極に衝突又は近傍を通過するときに生じる電荷の移動を利用することによって,主に極低濃度から高濃度領域までのダスト濃度を測定する摩擦静電気検出方式のダスト濃度自動計測器について規定。

JISB7997-3 規格全文情報

規格番号
JIS B7997-3 
規格名称
排ガス中のダスト濃度自動計測器-第3部:摩擦静電気検出方式
制定年月日
2020/06/22
最新改正日
JIS 閲覧
 
対応国際規格

ISO

国際規格分類

ICS

13.040.40,71.040.40
主務大臣
経済産業
JISハンドブック
改訂:履歴
  • 2020-06-22制定日

 

B 7997-3:2020 

 

目 次

ページ

1 適用範囲························································································································· 1

2 引用規格························································································································· 1

3 用語及び定義 ··················································································································· 1

4 測定原理及び用途 ············································································································· 1

4.1 測定原理 ······················································································································ 1

4.2 用途 ···························································································································· 2

5 計測器の測定レンジ ·········································································································· 2

6 計測器の性能 ··················································································································· 2

7 構成及び構造 ··················································································································· 3

7.1 構成 ···························································································································· 3

7.2 構造 ···························································································································· 3

7.3 使用温度範囲 ················································································································ 3

8 試験······························································································································· 3

8.1 試験条件 ······················································································································ 3

8.2 試験粉体 ······················································································································ 3

8.3 校正 ···························································································································· 3

8.4 相関係数 ······················································································································ 3

8.5 振動安定性 ··················································································································· 4

8.6 温度安定性 ··················································································································· 4

8.7 電源電圧安定性 ············································································································· 4

8.8 繰返し性 ······················································································································ 4

8.9 ゼロドリフト ················································································································ 4

8.10 スパンドリフト ············································································································ 4

8.11 応答時間 ····················································································································· 4

8.12 絶縁抵抗 ····················································································································· 4

8.13 耐電圧 ························································································································ 4

9 検査······························································································································· 4

10 報告書 ·························································································································· 5

11 表示 ····························································································································· 5

附属書A(参考)ゼロ校正及びスパン校正の例 ·········································································· 6

附属書B(参考)計測器の性能試験検査に関する報告書の例 ························································· 7

 

 

[ JIS B7997 : 3 : 2020.pdf Page : 1 / 9 ]ページ TOPへ

 

 

 

B 7997-3:2020 

 

まえがき

この規格は,産業標準化法に基づき,日本産業標準調査会の審議を経て,経済産業大臣が制定した日本

産業規格である。

この規格は,著作権法で保護対象となっている著作物である。

この規格の一部が,特許権,出願公開後の特許出願又は実用新案権に抵触する可能性があることに注意

を喚起する。経済産業大臣及び日本産業標準調査会は,このような特許権,出願公開後の特許出願及び実

用新案権に関わる確認について,責任はもたない。

 

 

[ JIS B7997 : 3 : 2020.pdf Page : 2 / 9 ]ページ TOPへ

 

 

 

 

日本産業規格          JIS

 

B 7997-3:2020

 

排ガス中のダスト濃度自動計測器−第3部:摩擦静電気検出方式

Automated concentration monitoring instrument of dust in flue gas-Part 3: Triboelectric measuring method

 

1

適用範囲

この規格は,排ガス中にプローブ状の電極を挿入したとき,ダストが電極に衝突又は近傍を通過すると

きに生じる電荷の移動を利用することによって,主に極低濃度から高濃度領域までのダスト濃度を測定す

る目的に使用する摩擦静電気検出方式のダスト濃度自動計測器(以下,計測器という。)について規定する。

注記 この規格では,極低濃度は5 mg/m3以下,低濃度は10 mg/m3以下,中濃度は50 mg/m3以下,及

び高濃度は50 mg/m3超えをいう。また,この規格に示すダスト濃度は,標準状態[273.15 K(0 ℃),

101.32 kPa]かつ乾き状態に換算した値である。

 

2

引用規格

次に掲げる規格は,この規格に引用されることによって,この規格の規定の一部を構成する。これらの

引用規格は,その最新版(追補を含む。)を適用する。

JIS B 7996 排ガス中のダスト濃度自動計測器の性能評価方法

JIS K 0211 分析化学用語(基礎部門)

JIS K 0215 分析化学用語(分析機器部門)

JIS Z 8103 計測用語

JIS Z 8808 排ガス中のダスト濃度の測定方法

JIS Z 8852 排ガス中のダスト濃度の連続測定方法

JIS Z 8901 試験用粉体及び試験用粒子

 

3

用語及び定義

この規格で用いる主な用語及び定義は,JIS B 7996,JIS K 0211,JIS K 0215,JIS Z 8103,JIS Z 8808,

JIS Z 8852及びJIS Z 8901による。

 

4

測定原理及び用途

4.1

測定原理

二つの固体粒子が接触すると,粒子間で電荷の移動が起こる。この電荷の移動は,摩擦静電気又は接触

帯電として知られている。同様に,排ガス中にプローブ状のセンサを挿入し,気体中の粒子が電極に衝突

又は近傍を通過することによって,粒子とセンサとの間で電荷の移動及び誘導現象が生じる。発生した摩

擦電流又は交流電流Iは,ダスト濃度に比例する。摩擦静電気に基づくものには,次の二つの方式がある。

[ JIS B7997 : 3 : 2020.pdf Page : 3 / 9 ]ページ TOPへ

 

 

2

B 7997-3:2020 

 

a) 摩擦電流式 センサへの電荷の移動で発生する摩擦電流からダスト濃度を求める方式

b) 交流電流式 センサに誘起される交流電流からダスト濃度を求める方式

a) 及びb) 共に,摩擦電流又は交流電流Iは,式(1)によって近似的に求めることができる。

p

d

kCv

I

Z

 ················································································· (1)

ここに,

I: 摩擦電流又は交流電流(A)

 

C: ダスト濃度(mg/m3)

 

v: 流速(m/s)

 

Z: 係数

 

dp: 粒子径(µm)

 

k: 定数

 

注記1 計測器は周辺の荷電の影響を受けやすいので,電気集じん装置の直後に設置する場合は注意

を要する。

注記2 ここに示すダスト濃度は,標準状態ではなく,実際の排ガスの温度及び圧力状態での値であ

る。

4.2

用途

この計測器は,主に廃棄物焼却施設,セメント工場及び製鉄所で使用する燃料の燃焼及びその他の燃焼

に伴って排出される流速変動の少ない排ガス中のダスト濃度を長期間かつ連続的に測定し,主にバグフィ

ルタの異常検出,燃焼管理及び排出量監視を目的として使用する。

 

5

計測器の測定レンジ

計測器の測定レンジは,通常,0 mg/m3〜1 000 mg/m3とし,それ以外のレンジは,用途に合わせて適切

なものを選ぶ。

 

6

計測器の性能

計測器は,箇条8によって試験を行ったとき,表1の性能を満足しなければならない。

 

表1−計測器の性能

項目

性能

試験方法

相関係数

0.9以上

8.4

振動安定性

0 mg/m3〜1 000 mg/m3 a) の

測定レンジ

試験前の指示値に対してフルスケー

ルの±2 %

8.5

温度安定性

10 ℃当たりフルスケールの±2 %

8.6

電源電圧安定性

フルスケールの±2 %

8.7

繰返し性

フルスケールの±2 %

8.8

ゼロドリフト

フルスケールの±2 %

8.9

スパンドリフト

フルスケールの±2 %

8.10

応答時間

60 s以内

8.11

絶縁抵抗

5 MΩ以上

8.12

耐電圧

異常がない

8.13

注a) 0 mg/m3〜1 000 mg/m3の測定レンジに対する試験ができない場合は,1 000 mg/m3以下の測定レンジ

で試験を行い,そのフルスケールの±2 %を性能値としてもよい。

 

[ JIS B7997 : 3 : 2020.pdf Page : 4 / 9 ]ページ TOPへ

 

 

JIS B 7997-3:2020の国際規格分類一覧

  • 13.040.40
  • 71.040.40

JIS B 7997-3:2020の関連規格と引用規格一覧

規格番号
規格名称
B7996
排ガス中のダスト濃度自動計測器の性能評価方法
K0211
分析化学用語(基礎部門)
K0215
分析化学用語(分析機器部門)
Z8103
計測用語
Z8808
排ガス中のダスト濃度の測定方法
Z8852
排ガス中のダスト濃度の連続測定方法
Z8901
試験用粉体及び試験用粒子