JIS A 1967:2015 室内空気中の揮発性有機化合物(VOC)の吸着捕集・加熱脱離・キャピラリーガスクロマトグラフィーによるサンプリング及び分析―パッシブサンプリング | ページ 8

                                                                                             33
A 1967 : 2015
[35] BROWN, R. H., CHARLTON, J., SAUNEERS, K. J. The developement of an improved diffusive sampler. Am.
Ind. Hyg. Assoc. J., 42 (1981), pp.865-869
[36] HEARL, F. J., MANNING, M. P. Transient response of diffusive dosimeters. Am. Ind. Hyg. Assoc. J., 41 (1980),
pp.778-783
[37] UNDERHILL, D. W.: Unbiased passive sampling. Am. Ind. Hyg. Assoc. J., 44 (1983), pp.237-239
[38] HORI, H., TANAKA, I.: Response characteristics of the diffusive sampler at fluctuating vapor concentrations.
Am. Ind. Hyg. Assoc. J., 54 (1993), pp.95-101
[39] COMPTON, J. R., DWIGGINS, G. A., FELGLEY, C. E., LUDWIG, D. A.: The effect of square-wave exposure
profiles upon the performance of passive organic vapor monitoring badges. Am. Ind. Hyg. Assoc. J., 45 (1984),
pp.446-450
[40] TOMPKINS F. C. and GOLDSMITH, R. L.: A new personal dosimeter for the monitoring of industrial
pollutants. Am, Ind. Hyg. Assoc. J., 38 (1977), 371-377
[41] UNDERHILL, D. W., FEIGLEY, C. E.: Boundary layer effect in diffusive monitoring. Anal. Chem. 63 (1991),
1011-1013
[42] POZZOLI, L., COTTICA, D. An overview of the effects of temperature, pressure, humidity, storage and face
velocity. Diffusive Sampling, an alternative approach to workplace air monitoring. Eds Berlin, A., Brown, R. H.
and Saunders, K. J., EC Publ. No. 10555 EN, Brussels-Luxembourg (1987), pp.119-130
[43] ZURLO, N., ANDREOLETTI, F.: Effect of air turbulence on diffusive sampling. Diffusive Sampling, an
alternative approach to workplace air monitoring. Eds Berlin, A., Brown, R. H. and Saunders, K. J., EC Publ.
No. 10555 EN, Brussels-Luxembourg (1987), pp.174-176
[44] COLEMAN, S. R. A tube-type diffusive monitor for sulphur dioxide. Am. Ind. Hyg. Assoc. J., 44 (1983),
pp.929-936
[45] PALMES, E. D., GUNNISON, A. F., DIMATTIO, J., TOMCZYK, C. Personal sampler for nitrogen dioxide.
Am. Ind. Hyg. Assoc. J., 37 (1976), pp.570-577
[46] GAIR, A. J., PENKETT, S. A. The effects of wind speed and turbulence on the performance of diffusion tube
samplers. Atmos. Env. 29 (1995), pp.2529-2533
[47] DOWNING, C. E. C., CAMPBELL, G. W., BAILEY, J. C. A survey of sulphur dioxide, ammonia and
hydrocarbon concentrations in the United Kingdom using diffusion tubes: July to December 1992. Warren
Spring Laboratory, Stevenage, UK, Report LR 964 (1994)
[48] FERM, M. A sensitive diffusional sampler. Institutet for Vatten och Luftvardsforskning, Sweden, Report B 1020

(pdf 一覧ページ番号 )

[49] PANNWITZ, K. H. Influence of air currents on the sampling of organic solvent vapours with diffusive samplers.
In Diffusive Sampling, an alternative approach to workplace air monitoring. Eds Berlin, A., Brown, R. H. and
Saunders, K. J., EC Publ. No. 10555 EN, Brussels-Luxembourg (1987), pp.157-160
[50] MARK, D., ROBERTSON, A., GIBSON, H., BORZUCKI, G., CHERRIE, B., MACLAREN, W. M. Evaluation
of diffusive samplers for monitoring toxic gases and vapours in coalmines. Institute of Occupational Medicine,
Edinburgh, Report TM/90/11 (1990)
[51] MATTHEWS, T. W., THOMPSON, C. V., WILSON, D. L., HAWTHORNE, A. R., MAGE, D. T. Air velocities
inside domestic environments: an important parameter for passive monitoring. Indoor air '87−Proc. 4th Intern.
Conf. on Indoor Air Quality and Cimate. Eds. B Seifert et. al. Inst. for Water, Soil and Air Hygiene, Berlin, 1

――――― [JIS A 1967 pdf 36] ―――――

34
A 1967 : 2015
(1987), pp.174-178
[52] PLANT, N. T., WRIGHT, M. D. European Diffusive Sampling Initiative: Pilot surveys of Sheffield. Health and
Safety Laboratory, Sheffield, Reprot IACS/96/1 (1996)
[53] TROEN, I., PETERSEN, E. L. European-windatlas, RISO National Laboratory, Roskilde, Denmark (1990)
ISBN 87-550-1636-7
[54] CHRISTOFFER, J., ULBRICHT-EISSING, M. Die bodennahen Windverhltnisse in der BR Deutschland,
Berichte des Deutschen Wetterdienstes 147, Offenbach-a.-M. (1989)
[55] HAFKENSCHEID, T. L., MOWRER, J. Intercomparison of tube-type diffusive sampling for the detemination of
volatile hydrocarbons in ambient air. Analyst, 121 (1996), pp.1249-1252
[56] PLANT, N. T., WRIGHT, M. D. European Diffusive Sampling Initiative:UK national survey of BTX. Health and
Safety Laboratory, Sheffield, Report IACS/97/6 (1997), Health and Safety Laboratory, Broad Lane, Sheffield S3
7HQ, UK
[57] VDI 2119, Part 4. Measurement of particulate percipitations: microscopic differentiation and size fraction
determination of particle deposition on adhesive collection plates: Sigma-2 sampler (1997)
[58] REMPLER, P. und Kosmus, W. Integrale Langzeitmethode zur Bestimmung von Ozon in der Atmosphre.
Fresenius Z. Anal. Chem., 329 (1998), pp.871-874
[59] JIS A 1960 室内空気のサンプリング方法通則
注記 ISO 16000-1:2004,Indoor air−Part 1: General aspects of sampling strategy(MOD)

――――― [JIS A 1967 pdf 37] ―――――

                                                                                                                                          35
A 1967 : 2015
附属書JB
(参考)
JISと対応国際規格との対比表
ISO 16017-2:2003,Indoor, ambient and workplace air−Sampling and analysis of
JIS A 1967:2015 室内空気中の揮発性有機化合物(VOC)の吸着捕集・加熱脱離・
volatile organic compounds by sorbent tube/thermal desorption/capillary gas
キャピラリーガスクロマトグラフィーによるサンプリング及び分析−パッシブサン
プリング chromatography−Part 2: Diffusive sampling
(I) JISの規定 (II) (III)国際規格の規定 (IV) JISと国際規格との技術的差異の箇条(V) JISと国際規格との技術的差
国際規格 ごとの評価及びその内容 異の理由及び今後の対策
番号
箇条番号 内容 箇条番号 内容 箇条ごと 技術的差異の内容
及び題名 の評価
2 引用規

3 用語及 この規格で用いる − − 追加 関連するJIS(ISO規格)との 技術的な差異はない。
び定義 主な用語及び定義 記載の統一化 次回のISO規格の改正時に修正
は,JIS A 1966によ を提案する。
る。
5 試薬・材試薬,標準溶液の調 4 JISとほぼ同じ 変更 ケトンをカルボン酸に修正し アルコールと縮合するのはケト
料 製方法などを規定。 た。 ンではなくカルボン酸であるた
め修正した。次回のISO規格の改
正時に提案を検討する。
5.2 希釈溶媒 4.2 希釈溶媒 削除 次回のISO規格の改正時に修正
酢酸エチル,シクロヘキサンな
どはVOCの成分になる場合が を提案する。
あるので削除した。
6 装置 6.1 サンプラ 5 5.1 サンプラ 追加 実質的な差異はない。 次回のISO規格の改正時に修正
を提案する。
6.3 サンプラサンプ 5.3 サンプラサンプリン 追加 実質的な差異はない。
リングキャップ グキャップ
6.5 ガスクロマトグ 5.5 ガスクロマトグラフ 変更 条件の緩和
A1
ラフ トルエン0.5 ng
967
トルエン1 ng
: 2
8 サンプ 現場ブランク 7 トラベルブランク 変更 実質的な差異はない。 技術的な差異はない。
0 1
3
リング
5
5

――――― [JIS A 1967 pdf 38] ―――――

    36
A 1967 : 2015
A1
3
(I) JISの規定 (II) (III)国際規格の規定 (IV) JISと国際規格との技術的差異の箇条(V) JISと国際規格との技術的差
6
9
国際規格 ごとの評価及びその内容 異の理由及び今後の対策
67
番号
: 2
箇条番号 内容 箇条番号 内容 箇条ごと 技術的差異の内容
0
及び題名 の評価
15
9.2.1 脱離 キャリヤーガスに 8.2.1 キャリヤーガスにヘリウ 追加 JISでは,冷却の程度によって次回のISO規格の改正時に修正
ヘリウム又は窒素 ムを用いる。 を提案する。
窒素を選択できることとした。
を用いる。
9.6 拡散 拡散取込み速度 8.6 − 追加 拡散取込み速度の意味を明確 実質的な差異はない。
取込み速 (Diffusive uptake 化するため,原文を引用した。
度の算出 rate)
10.1 分析 記号の変更 9.1 JISとほぼ同じ 変更 関連するJIS(ISO規格)の記 技術的な差異はない。
対象成分 号の統一化 次回のISO規格の改正時に修正
の質量濃 を提案する。

10.2 分析 記号の変更 9.2 JISとほぼ同じ 変更 関連するJIS(ISO規格)の記 技術的な差異はない。
対象成分 号の統一化 次回のISO規格の改正時に修正
の体積比 を提案する。
10.3 拡散 記号の変更 9.3 JISとほぼ同じ 変更 関連するJIS(ISO規格)の記 技術的な差異はない。
取込み速 号の統一化 次回のISO規格の改正時に修正
度u及び を提案する。
u'の関係
14 品質管 表7 単位μg 13 JISとほぼ同じ 変更 mgをμgに変更した。 ISO規格の誤り。
理 mg 次回のISO規格の改正時に修正
を提案する。
附属書A
A.1 原理
附属書JA
(参考)

――――― [JIS A 1967 pdf 39] ―――――

                                                                                                                                          37
A 1967 : 2015
JISと国際規格との対応の程度の全体評価 : ISO 16017-2:2003,MOD
注記1 箇条ごとの評価欄の用語の意味は,次による。
− 削除·················· 国際規格の規定項目又は規定内容を削除している。
− 追加·················· 国際規格にない規定項目又は規定内容を追加している。
− 変更·················· 国際規格の規定内容を変更している。
注記2 JISと国際規格との対応の程度の全体評価欄の記号の意味は,次による。
− MOD··············· 国際規格を修正している。
A1 967 : 2
0 1
3
5
7

――――― [JIS A 1967 pdf 40] ―――――

次のページ PDF 41

JIS A 1967:2015の引用国際規格 ISO 一覧

  • ISO 16017-2:2003(MOD)

JIS A 1967:2015の国際規格 ICS 分類一覧

JIS A 1967:2015の関連規格と引用規格一覧