39
B 1757-3 : 2013
表D.2−形状偏差δHの計算例
η0=1.732 1 mm,Y0=22.782 4 mm,tanε0=0.412 28
Zw mm εm rad ηm mm δH μm
1 −30 0.078 030 19.052 6 293.7
2 −28 0.098 898 17.897 9 235.4
3 −26 0.119 766 16.743 2 184.7
4 −24 0.140 633 15.588 5 141.1
5 −22 0.161 501 14.433 8 104.2
6 −20 0.182 369 13.279 1 73.4
7 −18 0.203 237 12.124 4 48.3
8 −16 0.224 105 10.969 7 28.3
9 −14 0.244 972 9.815 0 13.1
10 −12 0.265 840 8.660 3 2.2
11 −10 0.286 708 7.505 6 −5.0
12 −8 0.307 576 6.350 9 −8.7
13 −6 0.328 444 5.196 2 −9.7
14 −4 0.349 312 4.041 5 −8.2
15 −2 0.370 179 2.886 8 −4.8
16 0 0.391 047 1.732 1 0.0
17 2 0.411 915 0.577 4 5.7
18 4 0.432 783 −0.577 4 11.8
19 6 0.453 651 −1.732 1 17.7
20 8 0.474 518 −2.886 8 22.9
21 10 0.495 386 −4.041 5 26.8
22 12 0.516 254 −5.196 2 28.8
23 14 0.537 122 −6.350 9 28.1
24 16 0.557 990 −7.505 6 24.2
25 18 0.578 858 −8.660 3 16.3
26 20 0.599 725 −9.815 0 3.6
27 22 0.620 593 −10.969 7 −14.7
28 24 0.641 461 −12.124 4 −39.6
29 26 0.662 329 −13.279 1 −71.9
30 28 0.683 197 −14.433 8 −112.8
31 30 0.704 064 −15.588 5 −163.3
――――― [JIS B 1757-3 pdf 41] ―――――
40
B 1757-3 : 2013
参考文献
[1] ISO 1328-1,Cylindrical gears−ISO system of accuracy−Part 1: Definitions and allowable values of
deviations relevant to corresponding flanks of gear teeth
[2] ISO 18653,Gears−Evaluation of instruments for the measurement of individual gears
[3] ISO/TR 10064-5,Cylindrical gears−Code of inspection practice−Part 5: Recommendations relative to
evaluation of gear measuring instruments
[4] Masaharu Komori, Fumi Takeoka, Aizoh Kubo, Kazuhiko Okamoto, Sonko Osawa, Osamu Sato and Toshiyuki
Takatsuji, Evaluation method of lead measurement accuracy of gears using a wedge artefact, Measurement
Science and Technology, Volume 20, Number 2, February 2009, 025109.
[5] Masaharu Komori, Fumi Takeoka, Aizoh Kubo, Kazuhiko Okamoto, Sonko Osawa, Osamu Sato, Toshiyuki
Takatsuji, and Yohan Kondo, Artifact Design and Measurement Error Analysis in the Evaluation of Lead
Measurement Accuracy of Helical Gear Using Wedge Artifact, Journal of Mechanical Design, Vol. 132, Issue 7,
071006-1-11, 2010-7.
[6] Yohan Kondo, Koshi Kondo, Sonko Osawa, Osamu Sato, Masaharu Komori, Fumi Takeoka, Aizo Kubo,
Kazuhiko Okamoto and Kazuyuki Sasajima “Evaluation of instruments for helix measurement using wedge
artifact” Precision Engineering, 34, 667-674,2010
JIS B 1757-3:2013の国際規格 ICS 分類一覧
- 21 : 一般的に使用される機械的システム及び構成要素 > 21.200 : 歯車
- 17 : 度量衡及び測定.物理的現象 > 17.040 : 線及び角度の測定 > 17.040.30 : 測定機器
JIS B 1757-3:2013の関連規格と引用規格一覧
- 規格番号
- 規格名称
- JISB0102:1999
- 歯車用語―幾何学的定義