Z 4573 : 2016 (ISO/ASTM 51650 : 2013)
参考文献
[1] ICRU Report 85a, Fundamenatl quantities and units for ionizing radiation (2011)
[2] ICRU Report 80, Dosimetry systems for use in radiation processing (2008)
[3] Kudoh, H., Celina, M., Malone, G. M., Kaye, R. J., Gillen, K. T., and Clough, R. L., “Pulsed e Beam Irradiation
of Polymers−A Comparison of Dose Rate Effects and LET Effects,” Radiation Physics and Chemistry, Vol 48,
1996, pp. 555-562
[4] Puig, J. R., Laizier, J., and Sundardi, F., “Le Film TAC, Dosimetre Plastique pour la Mesure Pratique des
Doses dIrradiation Recues en Sterilisation,” Proceedings from the Symposium, Bombay, on Radiosterilization
of Medical Products, STI/PUB/383, IAEA, Vienna, Austria, 1974, pp. 113-134
[5] Levine, H., McLaughlin, W. L., and Miller, A., “Temperature and Humidity Effects on the Gamma-Ray
Response and Stability of Plastic Dosimeters,” Radiation Physics and Chemistry, Vol 14, 1979, pp. 551-574
[6] McLaughlin, W. L., Humphreys, J. C., Radak, B. B., Miller, A., and Olejnik, T. A., “The Response of Plastic
Dosimeters to Gamma Rays and Electrons at High Dose Rates,” Radiation Physics and Chemistry, Vol 14, 1979,
pp. 533-550
[7] Tamura, N., Tanaka, R., Mitomo, S., Matsuda, K., and Nagai, S., “Properties of Cellulose Triacetate Dose
Meter,” Radiation Physics and Chemistry, Vol 18, 1981, pp. 947-956
[8] Tanaka, R., Mitomo, S., and Tamura, N., “Effect of Temperature, Relative Humidity, and Dose Rate on the
Sensitivity of Cellulose Triacetate Dosimeters to Electrons and Gamma-Rays,” International Journal of
Radiation and Isotopes, Vol 35, 1984, pp. 875-881
[9] McLaughlin, W. L., Uribe, R. M., and Miller, A., “Megagray Dosimetry (or Monitoring of Very Large Radiation
Doses),” Radiation Physics and Chemistry, Vol 22, 1983, pp. 333362
[10] Gehringer, P., Proksch, E., and Eschweiler, H., “Oxygen Effect in Cellulose Triacetate Dosimetry,” High Dose
Dosimetry, Proceedings of Symposium, Vienna, 1984, STI/PUB/671, IAEA, Vienna, Austria, 1985, pp.
333-344
[11] McLaughlin, W. L., Boyd, A. W., Chadwick, K. H., McDonald, J. C., and Miller, A., Dosimetry for Radiation
Processing, Taylor and Francis, London, 1989, pp 162-163
[12] Matsuda, K., and Nagai, S., “Studies on the Radiation-Induced Coloration Mechanism of the Cellulose
Triacetate Film Dosimeter,”International Journal of Radiation Application and Instruments, PartA, Vol 42,
1991, pp. 1215-1221
[13] Tanaka, R., Mitomo, S., Sunaga, H., Matsuda, K., and Tamura, N., “Manual of CTA Dose Meter,” JAERI-M
Report 82-033, Japan Atomic Energy Research Institute, Tokyo, Japan, 1982
[14] Sunaga, H., Tachibana, H., Tanaka, R., Okamoto, J., Terai, H., and Saito, T., “Study on Dosimetry of
Bremsstrahlung Radiation Processing,”Radiation Physics and Chemistry, Vol 42, 1993, pp. 749-752
[15] Abdel-Rehim, F., Abdel-Fattah, A. A., Ebrahim S., and Ali Z. I., “Improvement of the CTA Dosimetric
Properties by the Selection of Readout Wavelength and the Calculation of the Spectrophotometric Quantity,”
Applied Radiation and Isotopes, Vol 47, No 2, 1996, pp. 247-258
[16] Peimel-Stuglik, Z., Fabisiak, S., “A Comparison of the Performance Characteristics of Four Film Dosimeters in
a 10-MeV Electron Beam,” Applied Radiation and Isotopes, Vol 66, 2008, pp. 346-352
――――― [JIS Z 4573 pdf 11] ―――――
10
Z 4573 : 2016 (ISO/ASTM 51650 : 2013)
[17] TS Z 0032:2012 国際計量計測用語−基本及び一般概念並びに関連用語(VIM)
注記 対応国際規格 : ISO/IEC Guide 99:2007,International vocabulary of metrology−Basic and general
concepts and associated terms (VIM)(IDT)
[18] TS Z 0033:2012 測定における不確かさの表現のガイド
注記 対応国際規格 : ISO/IEC Guide 98-3:2008,Uncertainty of measurement−Part 3: Guide to the
expression of uncertainty in measurement (GUM:1995)(IDT)
[19] ASTM E 275-08:2013,Practice for describing and measuring performance of ultraviolet and visible
spectrophotometers
[20] ISO/ASTM 52701,Guide for performance characterization of dosimeters and dosimetry systems for use in
radiation processing
JIS Z 4573:2016の引用国際規格 ISO 一覧
- ISO/ASTM 51650:2013(IDT)