28
A 2102-1 : 2015
表F.3−窓の全面積の30 %がフレーム面積の断熱スペーサを備えた垂直窓の熱貫流率(UW)
単位 W/(m2・K)
グレージン Ug 窓の全面積の30 %がフレーム面積であり,そのUfが下に示す値のときの
グのタイプ 断熱スペーサを備えた垂直窓の熱貫流率
UW
0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.6 3.0 3.4 3.8 7.0
単層 5.7 4.2 4.3 4.3 4.4 4.5 4.5 4.6 4.6 4.8 4.9 5.0 5.1 6.1
2層又は3層 3.3 2.7 2.7 2.8 2.9 2.9 3.0 3.0 3.1 3.2 3.4 3.5 3.6 4.4
3.2 2.6 2.7 2.7 2.8 2.8 2.9 3.0 3.0 3.2 3.3 3.4 3.5 4.4
3.1 2.5 2.6 2.7 2.7 2.8 2.8 2.9 3.0 3.1 3.2 3.3 3.5 4.3
3.0 2.5 2.5 2.6 2.6 2.7 2.8 2.8 2.9 3.0 3.1 3.3 3.4 4.2
2.9 2.4 2.5 2.5 2.6 2.6 2.7 2.8 2.8 3.0 3.1 3.2 3.3 4.2
2.8 2.3 2.4 2.4 2.5 2.6 2.6 2.7 2.8 2.9 3.0 3.1 3.2 4.1
2.7 2.3 2.3 2.4 2.4 2.5 2.6 2.6 2.7 2.8 2.9 3.1 3.2 4.0
2.6 2.2 2.2 2.3 2.4 2.4 2.5 2.5 2.6 2.6 2.9 3.0 3.1 3.9
2.5 2.1 2.2 2.2 2.3 2.4 2.4 2.5 2.6 2.5 2.8 2.9 3.0 3.9
2.4 2.0 2.1 2.2 2.2 2.3 2.3 2.4 2.5 2.5 2.7 2.8 3.0 3.8
2.3 2.0 2.0 2.1 2.2 2.2 2.3 2.3 2.4 2.4 2.7 2.8 2.9 3.7
2.2 1.9 2.0 2.0 2.1 2.1 2.2 2.3 2.3 2.3 2.6 2.7 2.8 3.7
2.1 1.8 1.9 2.0 2.0 2.1 2.1 2.2 2.3 2.2 2.5 2.6 2.8 3.6
2.0 1.8 1.8 1.9 2.0 2.0 2.1 2.1 2.3 2.4 2.5 2.6 2.7 3.6
1.9 1.7 1.8 1.8 1.9 2.0 2.0 2.1 2.2 2.3 2.4 2.5 2.7 3.5
1.8 1.6 1.7 1.8 1.8 1.9 1.9 2.0 2.1 2.2 2.4 2.5 2.6 3.5
1.7 1.6 1.6 1.7 1.8 1.8 1.9 1.9 2.0 2.2 2.3 2.4 2.5 3.4
1.6 1.5 1.6 1.6 1.7 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.5 3.3
1.5 1.4 1.5 1.6 1.6 1.7 1.7 1.8 1.9 2.0 2.1 2.3 2.4 3.2
1.4 1.4 1.4 1.5 1.5 1.6 1.7 1.7 1.8 2.0 2.1 2.2 2.3 3.2
1.3 1.3 1.4 1.4 1.5 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2 3.1
1.2 1.2 1.3 1.3 1.4 1.5 1.5 1.6 1.7 1.8 1.9 2.1 2.2 3.0
1.1 1.2 1.2 1.3 1.3 1.4 1.5 1.5 1.6 1.7 1.9 2.0 2.1 3.0
1.0 1.1 1.1 1.2 1.3 1.3 1.4 1.4 1.6 1.7 1.8 1.9 2.0 2.9
0.9 1.0 1.1 1.1 1.2 1.3 1.3 1.4 1.5 1.6 1.7 1.8 2.0 2.8
0.8 0.9 1.0 1.1 1.1 1.2 1.2 1.3 1.4 1.5 1.7 1.8 1.9 2.8
0.7 0.9 0.9 1.0 1.1 1.1 1.2 1.2 1.3 1.5 1.6 1.7 1.8 2.7
0.6 0.8 0.9 0.9 1.0 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.8 2.6
0.5 0.7 0.8 0.9 0.9 1.0 1.0 1.1 1.2 1.3 1.4 1.6 1.7 2.5

――――― [JIS A 2102-1 pdf 31] ―――――

                                                                                             29
A 2102-1 : 2015
表F.4−窓の全面積の20 %がフレーム面積の断熱スペーサを備えた垂直窓の熱貫流率(UW)
単位 W/(m2・K)
グレージン Ug 窓の全面積の20 %がフレーム面積であり,そのUfが下に示す値のときの
グのタイプ 断熱スペーサを備えた垂直窓の熱貫流率
UW
0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.6 3.0 3.4 3.8 7.0
単層 5.7 4.7 4.8 4.8 4.8 4.9 4.9 5.0 5.0 5.1 5.2 5.2 5.3 6.0
2層又は3層 3.3 2.9 3.0 3.0 3.1 3.1 3.1 3.2 3.2 3.3 3.4 3.5 3.6 4.1
3.2 2.9 2.9 2.9 3.0 3.0 3.1 3.1 3.2 3.2 3.3 3.4 3.5 4.0
3.1 2.8 2.8 2.9 2.9 2.9 3.0 3.0 3.1 3.2 3.2 3.3 3.4 3.9
3.0 2.7 2.7 2.8 2.8 2.9 2.9 2.9 3.0 3.1 3.2 3.2 3.3 3.8
2.9 2.6 2.7 2.7 2.7 2.8 2.8 2.9 2.9 3.0 3.1 3.2 3.2 3.7
2.8 2.5 2.6 2.6 2.7 2.7 2.7 2.8 2.8 2.9 3.0 3.1 3.2 3.7
2.7 2.5 2.5 2.5 2.6 2.6 2.7 2.7 2.8 2.8 2.9 3.0 3.1 3.6
2.6 2.4 2.4 2.5 2.5 2.5 2.6 2.6 2.7 2.6 2.8 2.9 3.0 3.5
2.5 2.3 2.3 2.4 2.4 2.5 2.5 2.5 2.6 2.5 2.8 2.8 2.9 3.4
2.4 2.2 2.3 2.3 2.3 2.4 2.4 2.5 2.5 2.4 2.7 2.8 2.8 3.3
2.3 2.1 2.2 2.2 2.3 2.3 2.3 2.4 2.4 2.4 2.6 2.7 2.8 3.3
2.2 2.1 2.1 2.1 2.2 2.2 2.3 2.3 2.4 2.3 2.5 2.6 2.7 3.2
2.1 2.0 2.0 2.1 2.1 2.1 2.2 2.2 2.3 2.2 2.4 2.5 2.6 3.1
2.0 1.9 2.0 2.0 2.0 2.1 2.1 2.2 2.3 2.3 2.4 2.5 2.6 3.1
1.9 1.8 1.9 1.9 2.0 2.0 2.0 2.1 2.2 2.3 2.3 2.5 2.5 3.0
1.8 1.8 1.8 1.8 1.9 1.9 2.0 2.0 2.1 2.2 2.3 2.3 2.4 2.9
1.7 1.7 1.7 1.8 1.8 1.8 1.9 1.9 2.0 2.1 2.2 2.3 2.3 2.9
1.6 1.6 1.6 1.7 1.7 1.8 1.8 1.8 1.9 2.0 2.1 2.2 2.3 2.8
1.5 1.5 1.6 1.6 1.6 1.7 1.7 1.8 1.9 1.9 2.0 2.1 2.2 2.7
1.4 1.4 1.5 1.5 1.6 1.6 1.6 1.7 1.8 1.9 1.9 2.0 2.1 2.6
1.3 1.4 1.4 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.9 1.9 2.0 2.5
1.2 1.3 1.3 1.4 1.4 1.4 1.5 1.5 1.6 1.7 1.8 1.9 1.9 2.5
1.1 1.2 1.2 1.3 1.3 1.4 1.4 1.4 1.5 1.6 1.7 1.8 1.9 2.4
1.0 1.1 1.2 1.2 1.2 1.3 1.3 1.4 1.5 1.5 1.6 1.7 1.8 2.3
0.9 1.0 1.1 1.1 1.2 1.2 1.2 1.3 1.4 1.5 1.5 1.6 1.7 2.2
0.8 1.0 1.0 1.0 1.1 1.1 1.2 1.2 1.3 1.4 1.5 1.5 1.6 2.1
0.7 0.9 0.9 1.0 1.0 1.0 1.1 1.1 1.2 1.3 1.4 1.5 1.5 2.1
0.6 0.8 0.8 0.9 0.9 1.0 1.0 1.0 1.1 1.2 1.3 1.4 1.5 2.0
0.5 0.7 0.8 0.8 0.8 0.9 0.9 1.0 1.1 1.1 1.2 1.3 1.4 1.9

――――― [JIS A 2102-1 pdf 32] ―――――

30
A 2102-1 : 2015
附属書G
(参考)
参考文献
[1] EN 12664,Thermal performance of building materials and products−Determination of thermal resistance by
means of guarded hot plate and heat flow meter methods−Dry and moist products of medium and low thermal
resistance
[2] EN 12667,Thermal performance of building materials and products−Determination of thermal resistance by
means of guarded hot plate and heat flow meter methods−Products of high and medium thermal resistance
[3] ift Guideline WA-01engl/2, Uf-values for thermal break metal profiles of window systems, ift Rosenheim,
February 2005
[4] ift Guideline WA-02engl/3, Uf-values for PVC profile sections of window systems, ift Rosenheim, February
2005
[5] ift Guideline WA-03engl/3, Uf-values for thermal break metal profile of facade systems, ift Rosenheim,
February 2005
[6] LAUSTSEN, J.B. and SVENDSEN, S. WIS Database: Data submission procedure for databases on spacer
profiles, edge constructions and window frame profiles, version 1.0, Technical University of Denmark, Dept.
of Civil Engineering, Lyngby, WinDat Document N2.11, March 2004
[7] ISO 12567-1,Thermal performance of windows and doors−Determination of thermal transmittance by the
hot-box method−Part 1: Complete windows and doors
[8] ISO 15099,Thermal performance of windows, doors and shading devices−Detailed calculations
[9] prEN 13947,Thermal performance of curtain walling−Calculation of thermal transmittance
[10] EN 13241-1,Industrial, commercial and garage doors and gates−Product standard−Part 1: Products without
fire resistance or smoke control characteristics
[11] EN 673,Glass in building−Determination of thermal transmittance (U value)−Calculation method
[12] EN 1279-1,Glass in building−Insulating glass units−Part 1: Generalities, dimensional tolerances and rules
for the system description
[13] EN 1279-3,Glass in building−Insulating glass units−Part 3: Long term test method and requirements for gas
leakage rate and for gas concentration tolerances
[14] ISO 10292,Glass in building−Calculation of steady-state U values (thermal transmittance) f multiple
glazing
[15] 赤坂裕,伊丹清,二宮秀與 : 断熱玄関ドアの熱貫流率の計算法,日本建築学会環境系論文集 No.502,
1997.12
[16] JIS A 1492 出窓及び天窓の断熱性試験方法
注記 対応国際規格 : ISO 12567-2,Thermal performance of windows and doors−Determination of thermal
transmittance by hot box method−Part 2: Roof windows and other projecting windows(MOD)
[17] JIS A 4702 ドアセット
[18] JIS A 4706 サッシ

――――― [JIS A 2102-1 pdf 33] ―――――

                                                                                             31
A 2102-1 : 2015
附属書JA
(規定)
出窓の熱貫流率
JA.1 概要
出窓は,屋外側に突出した窓形態であるため,二つの窓面積を基準に熱貫流率(UW)を計算する。一方
は4.4に従って得られる窓面積を用い,他方は展開窓面積を用いる。
出窓の計算対象は,屋根部・底部を除いた屋外側から窓の取付けアングルまでの範囲とする。
図JA.1に出窓の断面図及びフレームと屋根部又は底部との熱橋効果を算出するモデル化の範囲を示す。
1 フレーム a 室内側
2 グレージング(単層又は複層) b 屋外側
3 屋根部 W く(躯)体開口幅寸法
4 底部 H く(躯)体開口高さ寸法
5 フレームと屋根部又は底部との熱橋効果を
算出する範囲( より屋外側)
図JA.1−出窓の断面図及びモデル化の範囲
JA.2 出窓の熱貫流率
出窓の熱貫流率(UW)は,式(JA.1)によって計算する。
Ag Ug Af Uf lg Ψg ledge Ψedge
UW (JA.1)
AW
ここに, ledge : 上部又は下部のフレームと屋根部又は底部とが接する
見付け周囲長(m)
Ψedge : 屋根部,底部及びフレームの熱橋効果による線熱貫流率
[W/(m・K)]
AW : 窓面積(m2)

――――― [JIS A 2102-1 pdf 34] ―――――

32
A 2102-1 : 2015
出窓の上部フレーム及び下部フレームは,それぞれ屋根部又は底部と連結しているため,熱橋が形成さ
れ付加的な熱流が生じる。この熱流を,式(JA.1)の分子の第4項において線熱貫流率(Ψedge)として定義す
る。屋根部と底部がユニット化された窓製品では,それらの部位の詳細情報を得ることができるため,Ψedge
をJIS A 2102-2に従って計算しなければならない。
単層グレージングの場合,式(JA.1)の分子の第3項は無視できるので,ゼロ(スペーサによる影響なし)
とする。
Ugは,5.2に従って得なければならない。
Uf及びΨgは,JIS A 2102-2に従って計算しなければならない。
JA.3 出窓の窓面積
出窓の窓面積(AW)は,次のいずれかの方法によって計算しなければならない。
a) く(躯)体開口面積を伝熱開口面積とする場合 く(躯)体開口面積を伝熱開口面積とする場合は,
窓面積(AW)は,次の式(JA.2)によって計算する。図JA.1及びJIS A 4710を参照する。
AW W H (JA.2)
ここに, W : く(躯)体開口幅寸法(m)
H : く(躯)体開口高さ寸法(m)
b) 出窓の展開面積を伝熱開口面積とする場合 出窓の展開面積を伝熱開口面積とする場合は,窓面積
(AW)は,式(JA.3)によって計算する。
AW Ag Af (JA.3)
出窓の展開面積は,外壁から突出した窓の実面積(正面部・袖部)である。展開のための基準面をフレ
ームの見込み中央にとり,展開寸法を決定する。正面部及び袖部の実面積は,基準面に対するグレージン
グ及び各フレームの投影面積の積和とする。展開面積及び展開寸法の定義については,図JA.2を参照する。
1 展開寸法(展開基準面) 5 上部(フレーム)
2 方立部(フレーム) 6 下部(フレーム)
3 縦部(フレーム) a 室内側
4 グレージング(単層又は複層) b 屋外側
図JA.2−出窓の展開面積の例

――――― [JIS A 2102-1 pdf 35] ―――――

次のページ PDF 36

JIS A 2102-1:2015の引用国際規格 ISO 一覧

  • ISO 10077-1:2006(MOD)

JIS A 2102-1:2015の国際規格 ICS 分類一覧

JIS A 2102-1:2015の関連規格と引用規格一覧