JIS Z 4951:2017 医用電気機器―第2-33部:磁気共鳴画像診断装置の基礎安全及び基本性能に関する個別要求事項 | ページ 22

104
Z 4951 : 2017 (IEC 60601-2-33 : 2010,Amd.1 : 2013,Amd.2 : 2015)
[97] DEN BOER, JA., BAKKER, R., HAM, CGL., SMINK, J. Generalization to complex stimulus shape of the
nerve stimulation threshold based on existing knowledge of its relation to stimulus duration for rectangular
stimuli. Proceedings ISMRM 1999, p.108.
[98] SAUNDERS, RD., SIENKIEWICZ, ZJ. and KOWALCZUK, CI. Biological effects of electromagnetic fields
and radiation. J. Radiol. Prot., 1991, 11, p.27-42.
[99] BOTTOMLEY, PA. and ANDREW, ER. RF magnetic field penetration, phase shift and power dissipation in
biological tissue: Implications for NMR imaging. Phys. Med. Biol., 1978, 23, p.630-643.
[100] SCHENCK, JF. and HUSSAIN, MA. Power deposition during magnetic resonance. The effects of local
inhomogeneities and field exclusion. General Electric Corporate Research and development Labs. NMR
Project Memo No. 84-199, Oct 17, 1984.
[101] GANDHI, OP. and CHEN, JY. Absorption and Distribution Patterns of RF Fields. Annals of the New York
Academy of Sciences, 1992, 649, p.131-143.
[102] GRANDOLFO, M., POLICHETTI, A., VECCHIA, P. and GANDHI, OP. Spatial Distribution of RFPOwer in
Critical Organs during Magnetic resonance Imaging. Annals of the New York Academy of Sciences, 1992,
649, p.176-187.
[103] GABRIEL, C. Localised SAR in people undergoing NMR imaging. A report prepared for the National
Radiological Protection Board, Chilton, Didcot, Oxon, UK. by University Microwave, London, 1989.
[104] GRANDOLFO, M., VECCHIA, P., GANDHI, OP. Magnetic resonance imaging: Calculation of rates of
energy absorption by a human-torso model. Bioelectromagnetics, 1990, 11, p.117-128.
[105] ROWELL, LB. Cardiovascular aspects of human thermoregulation. Circ. Res., 1983, 52, p.367.
[106] International Radiation Protection Association (IRPA)/ International Non-Ionizing Radiation Committee
(INRC). Protection of the patient undergoing a magnetic resonance examination. Health Physics, 1991, 61,
p.923-928.
[107] KENNEY, WL. Physiological correlates of heat intolerance. Sports Med., 1985, 2, p.279-286.
[108] MINARD, D. Pre-employment and periodic medical examinations for workers on hot jobs. In
DUKES-DUBOS, FN and HENSCHEL, A., eds., Proceedings of a NIOSH Workshop on Recommended
Heat Stress Standards. Cincinnati, Ohio: U S Department of Health and Human Services, DHSS (NIOSH)
81-108, 1980, p.61-70.
[109] SMITH, DA., CLARREN, SK., HARVEY, MAS. Hyperthermia as a possible teratogenic agent. Pediatrics,
1978, 92, p.878-883.
[110] PLEET, H., GRAHAM JM. and SMITH, DW. Central nervous system and facial defects associated with
maternal hyperthermia at four to 14 weeks' gestation. Pediatrics, 1981, 67, p.785-789.
[111] ADAIR, ER., and BERGLUND, LG. On the thermoregulatory consequences of NMR imaging. Magn. Reson.
Imaging, 1986, 4, p.321-333.
[112] SCHAEFER, DJ., BARBER, BJ., GORDON, CJ., ZIELONKA, J., and HECKER, J. Thermal effects of
magnetic resonance imaging (MRI). In Abstracts: Society of Magnetic Resonance in Medicine. Volume 2.
Berkeley, California: Society of Magnetic Resonance in Medicine, 1985, p.925-926.
[113] KIDO, DK., MORRIS, TW., ERICKSON, JL., PLEWES, DB., and SIMON, JH. Physiologic changes during
high field strength MR imaging. Am J Neuroradiol, 1987, 8, p.263-266.
[114] ABART, J., BRINKER, G., IRLBACHER, W., GREBMEIER, J. Temperature and heart rate changes in MRI

――――― [JIS Z 4951 pdf 106] ―――――

                                                                                            105
Z 4951 : 2017 (IEC 60601-2-33 : 2010,Amd.1 : 2013,Amd.2 : 2015)
at SAR levels of up to 3 W/kg. Abstract, Society for Magnetic Resonance in Medicine, 1989 August, p.998.
[115] SHELLOCK, FG., SCHAEFER, DJ., CRUES, JV. Alterations in body and skin temperatures caused by
magnetic resonance imaging: is the recommended exposure for radio frequency radiation too conservative・
Brit. J. Radiol., 1989, 62, p.902-909.
[116] SCHAEFER, DJ.,. Dosimetry and effects of MR exposure to RF and switched magnetic fields. In MAGIN,
RI., LIBURDY, RP. and PERSSON, B., eds. Biological Effects and Safety Aspects of Nuclear Magnetic
Resonance Imaging and Spectroscopy. The New York Academy of Sciences, 1991, 649, p.225-236.
[117] NIOSH, 1986. Occupational exposure to hot environments. Revised criteria, 1986. National Institute for
Occupational Safety and Health, U.S. Dept. of Health and Human Services, DHHS (NIOSH), p.86-113.
[118] ADAIR, ER., and BERGLUND, LG., Thermoregulatory consequences of cardiovascular impairment during
NMR imaging in warm/humid environments. Magn. Reson. Imag. 1989, 7, p.25-37.
[119] ADAIR, ER. and BERGLUND LG. Predicted thermophysiological responses of humans to MRI fields. In
MAGIN, RI., LIBURDY, RP., and PERSSON, B., eds. Biological Effects and Safety Aspects of Nuclear
Magnetic Resonance Imaging and Spectroscopy. Annals of the New York Academy of Sciences, 1992, 649,
p.188-200.
[120] CZERSKI, P. and ATHEY, TW. Safety of magnetic resonance in vivo diagnostic examinations: Theoretical
and clinical considerations. Rockville, Maryland: Centre for Devices and Radiological Health, 1987.
[121] ATHEY, TW. A model of the temperature rise in the head due to magnetic resonance imaging procedures.
Magn. Reson. Med., 1989, 9, p.177-184.
[122] BARBER, BJ., SCHAEFER, DJ., GORDON, CJ., ZAWIEJA, DC. and HECKER, J. Thermal effects of MR
imaging: worst-case studies on sheep. American Journal of Roentgenology, 1990, 155, p.1105-1110.
[123] SCOTT, JA. A finite element model of heat transport in the human eye. Phys. Med. Biol., 1988, 33,
p.227-241.
[124] BOTTOMLEY, PA., and EDELSTEIN, WA. Power deposition in whole-body NMR imaging. Med. Phys.,
1981, 8, p.510-512.
[125] SHELLOCK, FG. and KANAL, E. Magnetic Resonance: Bioeffects, Safety and Patient Management. New
York: Lippincot Raven Press, 1996.
[126] SCHAEFER, DJ. Safety Aspects of Radio Frequency Power Deposition in Magnetic Resonance., E. Kanal,
ed. MRI Clinics of North America, 1998, 6(4), p.775-789.
[127] SHELLOCK, FG., Pocket Guide to MR Procedures and Metallic Objects: Update 2000. New York:
Lippincott Williams and Wilkins, 2000.
[128] SCHAEFER, DJ. and BOURLAND, JD. Review of Patient Safety in Time-Varying Gradient Fields. J of
Magn. Res. Imaging, 2000, 12(1), p.20-29.
[129] SHELLOCK, F.G., ed. Magnetic Resonance Procedures: Health Effects and Safety, CRC Press, 2001.
[130] Directive 2013/35/EU on the minimum health and safety requirements regarding the exposure of workers to
the risks arising from physical agents (electromagnetic fields);
http://eur-lex.europa.eu/LexUriServ/LexUriServ.do・uri=OJ:L:2013:179:0001:0021:EN:PDF.
[131] International Commission on Non-Ionizing Radiation Protection (ICNIRP), "Guidelines for limiting exposure
to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz)", Health Physics April 1998,
Volume 74, Number 4, pp 494-522.

――――― [JIS Z 4951 pdf 107] ―――――

106
Z 4951 : 2017 (IEC 60601-2-33 : 2010,Amd.1 : 2013,Amd.2 : 2015)
[132] International Commission on Non-Ionizing Radiation Protection (ICNIRP), "Medical magnetic resonance
(MR) rocedures: protection of patients", Health Physics August 2004, Volume 87, Number 2, pp 197-216.
[133] International Commission on Non-Ionizing Radiation Protection (ICNIRP), "Use of the ICNIRP EMF
guidelines", (March 31, 1999), http://www.icnirp.de/documents/Use.htm. p 2.
[134] American Conference of Government and Industrial Hygienists, Threshold Limit Values for Chemical
Substances and Physical Agents and Biological Exposure Indices, 1994, p.89.
[135] LEHNINGER, A.L., Biochemistry, 1970, Worth, New York, pp 40-41.
[136] SCHAEFER, D.J., "Safety Aspects of Switched Gradient Fields", MRI Clinics of North America, vol. 6, No.
4, November, 1998, p.743.
[137] U.S. Nuclear Regulatory Commission, 10 CFR 20 subpart C, at
http://www.nrc.gov/reading-rm/doc-collections/cfr/part020/.
[138] J.A. NYENHUIS, J.D. BOURLAND, A.V. KILDISHEV and D.J. SCHAEFER, "Health Effects and Safety of
Intense MRI Gradient Fields", in "Magnetic Resonance Procedures: Health Effects and Safety", pages 31-54,
edited by F.G. Shellock, CRC Press, 2001.
[139] J.A. DEN BOER, J.D. BOURLAND, J.A. NYENHUIS, C.L.G. HAM, J.M.L. ENGELS, F.X. HEBRANK, G.
FRESE, and D.J. SCHAEFER, "Comparison of the Threshold for Peripheral Nerve Stimulation during
Gradient Switching in Whole Body MR SYSTEMs, J. Magn. Reson. Imaging, Vol. 15, pp.520-525, 2002.
[140] J.M. DENEGRE, JR. J. M. VALLES, K. LIN, W. B. JORDAN, K. L. MOWRY, Cleavage planes in frog eggs
are altered by strong magnetic fields. Proc Natl Acad Sci, 95, 14729-32 1998
[141] WU, D. SHAMSI, S. CHEN, J. KAINZ, W. et al, “Evaluations of Specific Absorption Rate and Temperature
Increase Within Pregnant Female Models in Magnetic Resonance Imaging Birdcage Coils”, Microwave
Theory and Techniques, Volume: 54, Issue: 12, Part 2: 4472-4478, Dec. 2006
[142] ACR Guidance Document on MR safe Practices. J Mag Res Imaging, 2013, p.501-530.
Available at: http://onlinelibrary.wiley.com/doi/10.1002/jMRi.24011/pdf.
[143] World Health Organization, Environmental health Criteria 232, Static fields, 2006
[144] IEC 62570:2014,Standard practice for marking medical devices and other items for safety in the magnetic
resonance environment
[145] CROZIER, S., LIU, F. Numerical evaluation of the fields induced by body motion in or near high-field MRI
scanners. Prog in Biophysics & Molecular Biology, 2005, Vol 87, Nrs 2-3, pages 267-278
[146] Medical Electrical Installation Guidance,
http://www.mhra.gov.uk/Safetyinformation/Generalsafetyinformationandadvice/Technicalinformation/MEIG
aN-MedicalElectricalInstallationGuidance/index.htm
[147] Gowland P. and De Wilde, J. Temperature increase in the fetus due to RF exposure during MR scanning,
Phys. Med. Biol. 53, 2008, L15-L18
[148] Glover, P. M., Cavin, C., Qian, W., Bowtell, R. and Gowland P., Magnetic-Field induced Vertigo: A
Theoretical and Experimental Investigation, Bioelectromagnetics 28: 349−361, 2007
[149] Fuentes, M. A., Trakic, A., Wilson, S. J. and Crozier, S., Analysis and Measurements of Magnetic Field
Exposures for Healthcare Workers in Selected MR environments, IEEE Transactions on Biomedical
Engineering, Vol. 55, No. 4, p 1355, 2008
[150] MR Safey special issue, JMRI, Vol 26, 2007

――――― [JIS Z 4951 pdf 108] ―――――

                                                                                            107
Z 4951 : 2017 (IEC 60601-2-33 : 2010,Amd.1 : 2013,Amd.2 : 2015)
[151] Protection of Patients and Volunteers Undergoing MRI procedures, 2008, publication by the Health
Protection Agency, ISBN 978-0-85951-623-5,
http://www.hpa.org.uk/webw/HPAweb&HPAwebStandard/HPAwebC/1222673275443・p=1199451989432
[152] MHRA Device Bulletin, Safety guidelines for MRI equipment in clinical use, 2007
[153] EC study on 4 hospital sites: An investigation into occupational exposure ot electromagnetic fields for
personnel with and around medical MRI equipment, 2008
[154] IEEE C95.6: Standard for Safety Levels with Respect to Human Exposure to Electromagnetic Fields (0-3
kHz). New York: IEEE, 2002.
[155] Hoult, D.I. The Principle of Reciprocity in Signal Strength Calculations−A Mathematical Guide, Concepts
in Magnetic Resonance Part A, Wiley Periodicals, Vol. 12, pp.173-187, 2000.
[156] MRI Design Guide as published by the Department of Veterans Affairs.
http://www.va.gov/facmgt/standard/dguide/MRi/MRi01.pdf
[157] Collins, C.M., Mao, W. Liu, W., and Smith, M. B., Calculated Local and Average SAR in Comparison with
Regulatory Limits,14th Scientific Meeting and Exhibition held in Seattle, WA USA, 6-12 May 2006., p 2044
[158] den Boer J, Atalar E, Szimtenings M, Kleihorst R, Engels H., ISMRM Safety Workshop, 2005.
[159] Nadobny, J., Brinker G., Diehl D., Stetter E., Szimtenings M. and Wust P., Evaluation of MR-induced hot
spots for different temporal SAR modes using a time-dependent finite difference method with explicit
temperature gradient treatment, IEEE Trans Biomed Eng 54 (10) ct 2007, p 1837-1850
[160] Ellis, R.R. and Ellingson, R.J., “Responses to electrical stimulation of the median nerve in the human
newborn”, Developmental Psychobiology, Volume 6 Issue 3, Pages 235−244, Published Online: 13 Oct
2004
[161] Shellock, F. G., Crues, J. V., Temperature, heart rate and blood pressure changes associated with clinical
imaging at 1./5 T, Radiology, 163, 1987, p 259−262.
[162] International Commission on Non-Ionizing Radiation Protection (ICNIRP), Guidelines on limits of exposure
to static magnetic fields, Health Physics, 2009, Vol 96, Nr 4, p 504
[163] Hand, JF., Li, Y., Thomas, EL., Rutherford, MA. and Hajnal, JV. Prediction of Specific Absorption Rate in
mother and fetus associated with MRI examinations during pregnancy, Magnetic resonance in Medicine
2006, 55, p 883
[164] Wang, Z., Lin, JC., Mao, W., Liu, W., Smith, MB. and Collins CM. SA and temperature: Simulations and
comparison of regulatory limits for MRI, Journal of magnetic resonance 2007, 26, p 437
[165] IEC 60364-7-710,Electrical installations of buildings−Part 7-710: Requirements for special installations or
locations−Medical locations
[166] ISO 7010:2011,Graphical symbols−Safety colours and safety signs−Registered safety signs
[168] CHAKERES, DW, BORNSTEIN, R, and KANGARLU, A. Randomized Comparison of Cognitive Function
in Humans at 0 and 8 Tesla. J. Magn. Reson. Imaging, 2003;18:342-345
[169] LEPSIEN, J, MULLER, K, von CRAMON, D.Y, and MOLLER, H.E., Investigation of Higher-Order
Cognitive Functions During Exposure to a High Static Magnetic Field, J. Magn. Reson. Imaging, 2012;
36:835-840
[170] International Commission on Non-Ionizing Radiation Protection (ICNIRP), Amendment to the ICNIRP
“Statement on Medical Magnetic Resonance (MR) rocedures: Protection of Patients. Health Physics, 2009,

――――― [JIS Z 4951 pdf 109] ―――――

108
Z 4951 : 2017 (IEC 60601-2-33 : 2010,Amd.1 : 2013,Amd.2 : 2015)
Vol 97, Nr 3, p 259
[171] CHAKERES, DW, KANGARLU, A, BOUDOULAS, H, YOUNG, DC., Effect of static magnetic field
exposure of up to 8 tesla on sequential human vital sign measurements. J Magn Reson Imaging, 18:346-352;
2003a
[172] SIMI, S, BALLARDIN, M, CASELLA M, et al. Is the genotoxic effect of magnetic resonance negligible・
Low persistence of micronucleus frequency in lymphocytes of individuals after cardiac scan. Mutation Res
(2008) 645:39-43
[173] GHODBANE, S, LAHBIB, A, SAKLY, M, ABDELMELEK, H. Bioeffects of Static Magnetic Fields:
Oxidative Stress, Genotoxic Effects, and Cancer Studies, BioMed Research International (2013),
http://dx.doi.org/10.1155/2013/602987
[174] de VOCHT, F, van WENDELDE-JOODE, B, ENGELS, H, KROMHOUT, H.,Neurobehavioral effects among
subjects exposed to high static and gradient magnetic fields from a 1.5 tesla magnetic resonance imaging
system−a casecrossover pilot study. MAGN RESON MED 50:670-674; 2003
[175] NOLTE, CM, PITTMAN, DW, KALEVITCH, B, HENDERSON, R, SMITH, JC., Magnetic field
conditioned taste aversion in rats. Physiol Behav, 63:683-688; 1998
[176] OKAZAKI, R, OOTSUYAMA, A, UCHIDA, S, NORIMURA, T., Effects of a 4.7 T static magnetic field on
fetal development in ICR mice. J Radiat Res (Tokyo), 42:273-283; 2001
[177] SAUNDERS, RD. Static magnetic fields−animal studies. Prog Biophys Mol Biol 87:225-241; 2005
[178] UENO, S. and SHIGEMITSU, T. “Biological effects of static magnetic fields,” in Handbook of Biological
Effects of Electromagnetic Fields: Bioengineering and Biophysical Aspects of Electromagnetic Fields, F. S.
Barnes and B. Greenebaum, Eds., CRC Press, 3rd edition, 2007
[179] SCHENCK, JF, Physical interactions of static magnetic fields with living tissues. Prog Biophys Mol Biol,
87:185-204; 2005
[180] YAMAGUCHI-SEKINO, S, SEKINO, M, UENO, S., Biological effects of electromagnetic fields and
recently updated safety guidelines for strong static magnetic fields. Magn Reson Med Sci. 10:1-10; 2011
[181] ROBERTS, DC, MARCELLI, V, GILLEN, JS, CAREY, JP, DELLA SANTINA, CC, ZEE, DS. MRI
magnetic field stimulates rotational sensors of the brain. Curr Biol 2011; 21:1635-1640
[182] STEPHEN, T, DEUTSCHLANDER, A, NOLTE, A, SCHNEIDER, E, et al, “Functional MRI of galvanic
vestibular stimulation with alternating currents at different frequencies”. NeuroImage, 26:721-732; 2005
[183] TENFORDE, TS. Magnetically induced electric fields and currents in the circulatory system. Prog Biophys
Molec Biol, 87:279-288; 2005
[184] MIAN, OS, YAN, L, ANTUNES, A, GLOVER, PM, DAY, BL., On the Vertigo Due to Static Magnetic
Fields. PLoS ONE 8(10): e78748. doi:10.1371/journal.pone.0078748
[185] TRZECIAK, HI, GRZESIK, J, BORTEL, M, et al, Behavioral effects of long-term exposure to magnetic
fields in rats. Bioelectromagnetics, 14:287-297; 1993
[186] UENO, S, IWASAKA, M., Properties of diamagnetic fluid in high gradient fields,. J Appl Phys,
75:7177-7180; 1994
[187] WEISS, J, HERRICK, RC, TABER, KH, et al. .Bio-effects of high magnetic fields: a study using a simple
animal model. Magn Reson Imaging, 10:689-694; 1992.
[188] ZHANG, QM, TOKIWA, M, DOI, T, et al. .Strong static magnetic field and the induction of mutations

――――― [JIS Z 4951 pdf 110] ―――――

次のページ PDF 111

JIS Z 4951:2017の引用国際規格 ISO 一覧

  • IEC 60601-2-33:2010(IDT)
  • IEC 60601-2-33:2010/AMENDMENT 1:2013(IDT)
  • IEC 60601-2-33:2010/AMENDMENT 2:2015(IDT)

JIS Z 4951:2017の国際規格 ICS 分類一覧

JIS Z 4951:2017の関連規格と引用規格一覧

規格番号
規格名称
JISB7761-3:2007
手腕系振動―第3部:測定及び評価に関する一般要求事項
JISC0445:1999
文字数字の表記に関する一般則を含む機器の端子及び識別指定された電線端末の識別法
JISC0447:1997
マンマシンインタフェース(MMI)―操作の基準
JISC1509-1:2017
電気音響―サウンドレベルメータ(騒音計)―第1部:仕様
JISC1509-2:2018
電気音響―サウンドレベルメータ(騒音計)―第2部:型式評価試験
JISC2134:2007
固体絶縁材料の保証及び比較トラッキング指数の測定方法
JISC2134:2021
固体絶縁材料の保証及び比較トラッキング指数の測定方法
JISC4003:2010
電気絶縁―熱的耐久性評価及び呼び方
JISC60079-0:2010
爆発性雰囲気―第0部:電気機器―一般要件
JISC60079-2:2008
爆発性雰囲気で使用する電気機械器具―第2部:内圧防爆構造“p”
JISC60079-6:2004
爆発性雰囲気で使用する電気機械器具―第6部:油入防爆構造“o”
JISC60364-4-41:2010
低圧電気設備―第4-41部:安全保護―感電保護
JISC60695-11-10:2015
耐火性試験―電気・電子―第11-10部:試験炎―50W試験炎による水平及び垂直燃焼試験方法
JISC6965:2007
ブラウン管の機械的安全性
JISC8282-1:2019
家庭用及びこれに類する用途のプラグ及びコンセント―第1部:一般要求事項
JISC8303:2007
配線用差込接続器
JIST0601-1-3:2012
医用電気機器―第1-3部:基礎安全及び基本性能に関する一般要求事項―副通則:診断用X線装置における放射線防護
JIST60601-1-8:2012
医用電気機器―第1-8部:基礎安全及び基本性能に関する一般要求事項―副通則:医用電気機器及び医用電気システムのアラームシステムに関する一般要求事項,試験方法及び適用指針
JISZ8736-1:1999
音響―音響インテンシティによる騒音源の音響パワーレベルの測定方法―第1部:離散点による測定