T 80601-2-61 : 2014 (ISO 80601-2-61 : 2011)
[23] BLAND, J.M., ALTMAN, D.G. Statistical methods for assessing agreement between two methods of clinical
measurement. Lancet 1986-02-08, pp. 307-310
[24] BOIVIN, W. et al. Measurement of radiofrequency electromagnetic fields in and around ambulances.Biomed.
Instrum. Technol. 1997, 31 (2), pp. 145-154
[25] BOYLE, R.J., OH, W. Erythema following transcutaneous PO2 monitoring. Pediatrics 1980, 65 (2, Feb), pp.
333-334
[26] BUCHER, H.U., FANCONI, S., FALLENSTEIN, F., DUC, G. Transcutaneous carbon dioxide tension in
newborn infants: Reliability and safety of continuous 24-hour measurement at 42 °C. Pediatrics 1986, 78, pp.
631-635
[27] BURNETT, et al. Blood gas and pH analysis and related measurements. NCCLS, 21 (14) 2)
[28] CABAL, L., HODGMAN, J., SIASSI, B., PLAJSTEK, C. Factors affecting heated transcutaneous PO2 and
unheated transcutaneous PO2 in preterm infants. Crit. Care. Med. 1981, 9, pp. 298-304
[29] College of American Pathologists, CAP Laboratory Accreditation Programs 3)
[30] CUST, A.E., DONOVAN, T.J., COLDITZ, P.B. Alarm settings for the Marquette 8000 pulse oximeter to
prevent hyperoxic and hypoxic episodes, J. Paediatr. Child Health 1999, 35 (2), pp. 159-162
[31] EBERHARD, P., MINDT, W., JANN, F., HAMMACHER, K. Continuous PO2 monitoring in the neonate by
skin electrodes. Med. Biol. Eng. 1975, 13 (May), pp. 436-442
[32] EBERHARD, P., MINDT, W., KREUZER, F. Cutaneous oxygen monitoring in the newborn. Paediatrician
1976, 5, pp. 335-369
[33] FANCONI, S., TSCHUPP, A., MOLINARI, L. Long-term transcutaneous monitoring of oxygen tension and
carbon dioxide at 42 degrees C in critically ill neonates: Improved performance of the tcPO2 monitor with
topical metabolic inhibition. Eur. J. Pediatr. 1996, 155 (12, Dec), pp. 1043-1046
[34] FDA Draft Guidance Document: Non-Invasive Pulse oximeter, Center for Devices and Radiological Health,
Anesthesiology and Defibrillator Devices Branch, Division of Cardiovascular and Respiratory Devices, Office
of Device Evaluation. September 7, 1992
[35] FDA Draft Guidance Document: Pulse oximeters premarket notification submissions [510(k) s], Center for
Devices and Radiological Health, Anesthesiology and Defibrillator Devices Branch, Division of
Cardiovascular and Respiratory Devices, Office of Device Evaluation. July 19, 2007
[36] FDA Excerpts Related to EMI from Anesthesiology and Respiratory Devices Branch, November 1993. Section
(i) (7),17を参照。
[37] FDA Quality System Regulation: 21 CFR 820.3 (z): validation
[38] GEHRING, H., HORNBERGER, C., DIBBELT, L., ROTHSIGKEIT, A., GERLACH, K., SCHUMACHER, J.,
SCHMUCKER, P. Accuracy of point-of-care-testing (POCT) or determining haemoglobin concentrations.
Acta Anaesthesiol. Scand. 2002, 46, pp. 980-986
[39] GOLDEN, S.M. Skin craters−A complication of transcutaneous oxygen monitoring. Pediatrics 1981, 67 (4,
Apr), pp. 514-516
[40] GREENHALGH, D.G., LAWLESS, M.B., CHEW, B.B., CRONE, W.A., FEIN, M.E., PALMIERI, T.L.
Temperature threshold for burn injury: An oximeter safety study. J. Burn Care Rehabil. 2004, 25, pp. 411-415.
[41] Guidance for industry: Cardiac Monitor Guidance, 1998-11-05
[42] HARPIN, V.A., CHELLAPPAH, G., RUTTER, N. Responses of the newborn infant to overheating. Biol.
――――― [JIS T 80601-2-61 pdf 81] ―――――
79
T 80601-2-61 : 2014 (ISO 80601-2-61 : 2011)
Neonate 1983, 44 (2), pp. 65-75
[43] HORNBERGER, C., et al. Design and validation of a pulse oximeter calibrator, Anesth. Analg. 2002, 94, pp.
S8-S12
[44] HORNBERGER, C., et al. Prototype device for standardized calibration of pulse oximeters. J. Clin. Monit.
Comput. 2000, 3, pp. 161-169
[45] HUCH, R., HUCH, A., LBBERS, D.W. Transcutaneous PO2, p. 78. Stuttgart: Thieme, 1981
[46] HUCH, R., HUCH, A., LBBERS, D.W. Transcutaneous PO2. p. 91. Stuttgart: Thieme, 1981
[47] IAIZZO, P.A., KVEEN, G.L., KOKATE, J.Y., LELAND, K.J., HANSEN, G.L., SPARROW, E.M. Prevention
of pressure ulcers by focal cooling: histological assessment in a porcine model. In Wounds: A compendium of
clinical research and practice, 7 (5), 1995, pp. 161-169
[48] JASZCZAK, P., POULSEN, J. tcPO2 dependence on a sufficient blood flow. In: Continuous transcutaneous
blood gas monitoring. (Eds: HUCH, R., HUCH, A.) (Series Eds: SYMONDS, E.M., ZUSPAN, F.P.
Reproductive Medicine, Volume 5). New York, NY: Marcel Dekker, pp. 35-43, 1983a. (Papers presented at the
Second International Symposium on Continuous Transcutaneous Blood Gas Monitoring, at the University of
Zurich, 1981-10-14/16)
[49] JASZCZAK, P., POULSEN, J. The effects of a heated tcPO2 electrode on skin and blood temperature. In:
Continuous transcutaneous blood gas monitoring. (Eds: HUCH, R., HUCH, A.) (Series Eds: SYMONDS,
E.M., ZUSPAN, F.P. Reproductive Medicine, Volume 5). New York, NY: Marcel Dekker, pp. 45-55, 1983b.
(Papers presented at the Second International Symposium on Continuous Transcutaneous Blood Gas
Monitoring, at the University of Zurich, October 14-16, 1981)
[50] JUBRAN, A. Pulse oximetry, Crit. Care 4) 1999, 3 (doi:10.1186/cc341), pp. R11-R17
[51] KOKATE, J.Y., et al. Temperature-modulated pressure ulcers: a porcine model. Arch. Phys. Med. Rehab. 1995,
76, pp. 666-673
[52] LAPTOOK, A., OH, W. Transcutaneous carbon dioxide monitoring in the newborn period. Crit. Care Med.
1981, 9 (10), pp. 759-760
[53] LFGREN, O., ANDERSSON, D. Transcutaneous carbon dioxide and transcutaneous oxygen monitoring in
neonatal intensive care patients. In: Continuous transcutaneous blood gas monitoring. (Eds: HUCH, R.,
HUCH, A.) (Series Eds: SYMONDS, E.M., ZUSPAN, F.P. Reproductive Medicine, Volume 5). New York, NY:
Marcel Dekker, pp. 413-419, 1983. (Papers presented at the Second International Symposium on Continuous
Transcutaneous Blood Gas Monitoring, University of Zurich, October 14-16, 1981)
[54] LYNN, L.A. Interpretive oximetry: Future directions for the diagnostic application of the SpO2 timeseries.
Anesth. Analg. 2002, 94 (S1), pp. S84-88
[55] MALIN, S.W., BAUMGART, S. Optimal thermal management for low birth weight infants nursed under
high-powered radiant warmers. Pediatrics 1987, 79 (1, Jan), pp. 47-54
[56] MANZINGER, H. Temperaturgrenzen fr die Verbrennung der Haut−Ultraschall B Scan Untersuchung.
[Temperature limits for skin burning; ultrasound B scan investigation.] Dissertation, Medizinischen Fakultt
der Ludwig Maximilians Universitt zu Mnchen. p. 71, 1990
[57] MONACO, F., MCQUITTY, J.C. Transcutaneous measurements of carbon dioxide partial pressure in sick
neonates. Crit. Care Med. 1981, 9 (10), pp. 756-758
[58] MONCRIEF, J.A. The body's response to heat. In: Burns: a team approach. (Eds: ARTZ, C.P., MONCRIEF,
――――― [JIS T 80601-2-61 pdf 82] ―――――
80
T 80601-2-61 : 2014 (ISO 80601-2-61 : 2011)
J.A., PRUITT, B.A.) .B. Saunders, pp. 23-44, 1979
[59] MORITZ, A.R., HENRIQUES, F.C. Jr. Studies of thermal injury. I. The relative importance of time and
surface temperature in the causation of cutaneous burns. Am. J. Pathol. 1947, 23, pp. 695-720
[60] MORITZ, A.R., HENRIQUES, F.C. Jr. Studies of thermal injury. II. The relative importance of time and
surface temperature in the causation of cutaneous burns. Am. J. Pathol. 1947, 23, pp. 714-715
[61] PALREDDY, S. Signal processing algorithms. In: WEBSTER, J.G., editor. Design of pulse oximeters, p. 129 ff.
Bristol: Institute of Physics Publishing, 1997
[62] POLER, S.M., WALKER, S.S., KIBELBEK, M.J., MAROON, M. Cutaneous injuries associated with pulse
oximeters. J. Clin. Monit. 1992, 8 (2, April), p. 185
[63] PREIS, N, M.D. pediatric dermatologist, Duke University Medical Center, private communication to S.
Weitzner, M.D.
[64] RHEINECK-LEYSSIUS, A.T., KALKMAN, C.J. Influence of pulse oximeter lower alarm limit on the
incidence of hypoxaemia in the recovery room. Br. J. Anaesth. 1997, 79, pp. 460-464
[65] RYAN, T.J. Structure, pattern and shape of the blood vessels of the skin. In: JARRETT, ed., Physiology and
pathophysiology of the skin, pp. 577-651. London: Academic Press, 1973
[66] SCHACHINGER, H., SEILER, D. First experiences with transconjunctival PO2 measurement. In: Continuous
transcutaneous blood gas monitoring. (Eds: HUCH, R., HUCH, A.) (Series Eds: SYMONDS, E.M., ZUSPAN,
F.P. Reproductive Medicine, Volume 5). New York, NY: Marcel Dekker, 1983. (Papers presented at the Second
International Symposium on Continuous Transcutaneous Blood Gas Monitoring, at the University of Zurich,
October 14-16, 1981)
[67] SCHMITT, J. M. Simple photon diffusion analysis of the effects of multiple scattering on pulse oximetry.
IEEE Trans. Biomed. Eng. 1991, 38 (12), pp. 1194-1203; 1992, 39 (3), p. 314
[68] SEGUIN, J. Effects of transcutaneous monitor electrode heat on skin servo-controlled environments. J.
Perinatol. 1992, 12 (3, Sep), pp. 276-280
[69] SEVERINGHAUS, J.W., NAIFEH, K.H., KOH, S.O. Errors in 14 pulse oximeters during profound hypoxia. J.
Clin. Mon. 1989, 5, pp. 72-81
[70] SEVERINGHAUS, J.W., NAIFEH, K.H. Accuracy of response of six pulse oximeters to profound hypoxia.
Anesthesiology 1987, 67, pp. 551-558
[71] SEVERINGHAUS, J.W., KELLEHER, J.F. Recent developments in pulse oximetry. Anesthesiology 1992, 76
(6, June), pp. 1018-1038 (pp. 227-228)
[72] SEVERINGHAUS, J.W. private communication to ASTM F-29
[73] TEMPLEMAN, M.C., BELL, E.F. Head insulation for premature infants in servocontrolled incubators and
adiant warmers. Am. J. Dis. Child 1986, 140 (9, Sep), pp. 940-942
[74] TOPPER, W.H., STEWART, T.P. Thermal support for the very-low-birth-weight infant: Role of supplemental
conductive heat. J. Pediatr. 1984, 105 (5, Nov), pp. 810-814
[75] VENUS, B., PATEL, K.C., PRATAP, K.S., KONCHIGERI, H., VIDYASAGAR, D. Transcutaneous PO2
monitoring during pediatric surgery. Crit. Care Med. 1981, 9 (10), pp. 714-716
[76] VYAS, H., HELMS, P., CHERIYAN, G. Transcutaneous oxygen monitoring beyond the neonatal period. Crit.
Care Med. 1988, 16 (9, Sep), pp. 844-847
[77] WIENERT, V., SICK, H., ZUR MHLEN, J. Lokale thermische Belastbarkeit der menschlichen Haut [The
――――― [JIS T 80601-2-61 pdf 83] ―――――
81
T 80601-2-61 : 2014 (ISO 80601-2-61 : 2011)
local heat tolerance of the human skin]. Anasth. Intensivther. Notf. Med. 1983, 18, pp. 88-90
[78] ASTM F2761-09,Medical devices and medical systems−Essential safety requirements for equipment
comprising the patient-centric integrated clinical environment (ICE)−Part 1: General requirements and
conceptual model
[79] JIS Z 8103:2000 計測用語
注1) he National Fire Protection Association, 1 Batterymarch Park, PO Box 9101, Quincy, MA 02269-2101,
USAで入手可能。
2) CCLSのホームページで入手可能。http://www.nccls.org/free/C46-A.pdf
3) APのホームページで入手可能。
http://www.cap.org/apps/docs/laboratoryaccreditation/lapinfo/progdesccrit.pdf
4) ホームページで入手可能。http://ccforum.com/content/3/2/R11
――――― [JIS T 80601-2-61 pdf 84] ―――――
82
T 80601-2-61 : 2014 (ISO 80601-2-61 : 2011)
定義用語の索引
(ア) アラーム音中断 AUDIO PAUSED JIS T 60601-1-8:2012,3.13
アラームシステム ALARM SYSTEM JIS T 60601-1-8:2012,3.11
アラーム状態 ALARM CONDITION JIS T 60601-1-8:2012,3.1
アラーム状態遅延時間 ALARM CONDITION DELAY JIS T 60601-1-8:2012,3.2
アラーム初期設定 DEFAULT ALARM PRESET JIS T 60601-1-8:2012,3.16
アラーム信号 ALARM SIGNAL JIS T 60601-1-8:2012,3.9
アラーム信号発生遅延時間 ALARM SIGNAL GENERATION DELAY JIS T 60601-1-8:2012,3.10
アラーム設定状態 ALARM SETTINGS JIS T 60601-1-8:2012,3.8
アラーム設定値 ALARM LIMIT JIS T 60601-1-8:2012,3.3
アラーム中断 ALARM PAUSED JIS T 60601-1-8:2012,3.5
アラームプリセット ALARM PRESET JIS T 60601-1-8:2012,3.6
(イ) 移動形 MOBILE JIS T 0601-1:2012,3.65
イミュニティ試験レベル IMMUNITY TEST LEVEL IEC 60601-1-2:2007,3.15
医用電気機器(ME機器) MEDICAL ELECTRICAL EQUIPMENT JIS T 0601-1:2012,3.63
医用電気システム(MEシステム) MEDICAL ELECTRICAL SYSTEM JIS T 0601-1:2012,3.64
(オ) オキシヘモグロビン分画 FRACTIONAL OXYHAEMOGLOBIN 201.3.207
(カ) 外装 ENCLOSURE JIS T 0601-1:2012,3.26
患者 PATIENT JIS T 0601-1:2012,3.76
患者環境 PATIENT ENVIRONMNET JIS T 0601-1:2012,3.79
(キ) 危害 HARM JIS T 0601-1:2012,3.38
機器アラーム状態 TECHNICAL ALARM CONDITION JIS T 60601-1-8:2012,3.36
危険状態 HAZARDOUS SITUATION JIS T 0601-1:2012,3.40
基礎安全 BASIC SAFETY JIS T 0601-1:2012,3.10
機能試験器 FUNCTIONAL TESTER 201.3.209
機能的酸素飽和度 FUNCTIONAL OXYGEN SATURATION 201.3.208
基本性能 ESSENTIAL PERFORMANCE JIS T 0601-1:2012,3.27
局所かたより LOCAL BIAS 201.3.210
(ケ) 形式名称 MODEL OR TYPE REFERENCE JIS T 0601-1:2012,3.66
携帯形 PORTABLE JIS T 0601-1:2012,3.85
検証 VERIFICATION (VERIFY) JIS T 0601-1:2012,3.138
(コ) 公称範囲 DECLARED RANGE 201.3.205
(サ) 再生 REPROCESSING (REPROCESSED) 201.3.221
在宅医療環境 HOME HEALTHCARE ENVIRONMENT IEC 60601-1-11:2010,3.2
(シ) 情報信号 INFORMATION SIGNAL JIS T 60601-1-8:2012,3.23
信号入出力部 SIGNAL INPUT/OUTPUT PART JIS T 0601-1:2012,3.115
(ス) 据置形 STATIONARY JIS T 0601-1:2012,3.118
(セ) 正規化した NORMALIZED 201.3.212
――――― [JIS T 80601-2-61 pdf 85] ―――――
次のページ PDF 86
JIS T 80601-2-61:2014の引用国際規格 ISO 一覧
- ISO 80601-2-61:2011(IDT)
JIS T 80601-2-61:2014の国際規格 ICS 分類一覧
- 11 : 医療技術 > 11.040 : 医療設備 > 11.040.10 : 麻酔設備,呼吸設備及び蘇生設備
JIS T 80601-2-61:2014の関連規格と引用規格一覧
- 規格番号
- 規格名称
- JISB7761-3:2007
- 手腕系振動―第3部:測定及び評価に関する一般要求事項
- JISB9707:2002
- 機械類の安全性―危険区域に上肢が到達することを防止するための安全距離
- JISB9711:2002
- 機械類の安全性―人体部位が押しつぶされることを回避するための最小すきま
- JISC0445:1999
- 文字数字の表記に関する一般則を含む機器の端子及び識別指定された電線端末の識別法
- JISC0447:1997
- マンマシンインタフェース(MMI)―操作の基準
- JISC1509-1:2017
- 電気音響―サウンドレベルメータ(騒音計)―第1部:仕様
- JISC1509-2:2018
- 電気音響―サウンドレベルメータ(騒音計)―第2部:型式評価試験
- JISC2134:2007
- 固体絶縁材料の保証及び比較トラッキング指数の測定方法
- JISC2134:2021
- 固体絶縁材料の保証及び比較トラッキング指数の測定方法
- JISC4003:2010
- 電気絶縁―熱的耐久性評価及び呼び方
- JISC60079-0:2010
- 爆発性雰囲気―第0部:電気機器―一般要件
- JISC60079-2:2008
- 爆発性雰囲気で使用する電気機械器具―第2部:内圧防爆構造“p”
- JISC60079-6:2004
- 爆発性雰囲気で使用する電気機械器具―第6部:油入防爆構造“o”
- JISC60364-4-41:2010
- 低圧電気設備―第4-41部:安全保護―感電保護
- JISC60695-11-10:2015
- 耐火性試験―電気・電子―第11-10部:試験炎―50W試験炎による水平及び垂直燃焼試験方法
- JISC6965:2007
- ブラウン管の機械的安全性
- JISC8282-1:2019
- 家庭用及びこれに類する用途のプラグ及びコンセント―第1部:一般要求事項
- JISC8303:2007
- 配線用差込接続器
- JIST0307:2004
- 医療機器―医療機器のラベル,ラベリング及び供給される情報に用いる図記号
- JIST0601-1-3:2012
- 医用電気機器―第1-3部:基礎安全及び基本性能に関する一般要求事項―副通則:診断用X線装置における放射線防護
- JISZ8202:1985
- 量記号,単位記号及び化学記号
- JISZ8203:1964
- 単位記号
- JISZ8203:2000
- 国際単位系(SI)及びその使い方
- JISZ8736-1:1999
- 音響―音響インテンシティによる騒音源の音響パワーレベルの測定方法―第1部:離散点による測定